- 7. Mai 2023
- Posted by:
- Category: Allgemein
Before triggering scaling, reset the parameters with user-defined units. Communication channel (Hiperface) to encoder is subject to interference or motor encoder is inoperative. >w.?&")(.A7*YP]V4jrXA[Z79@dma,ARS1n(#0w*[: PEb&FECWEbSVNABAA])!I1$MA c]i`lGWe+rrP+IgPR@|u$ )=C~8EQEpP_5^8DMit B&Qr* tAPvHB"H8:XO!W=Wc#7q2'83U GL.%Nr =0Z}:LY`>p&V] Q(zBDZ;yJKRHk/g,[}(sVI`QvncXOt<0 6tgyZ*8q8VT=37%e?HUPUa#9A#cY zseYeCDq|gd5=g6P]:&efDcV.ee'olVAPhiPCVfN 'E5J7%']L !. }/@]J?V-.-LRGP)hL[jq(M)Z]N8j,'pJHW,K8C 0+GtZ? Detected motor type is different from previously detected motor. Bridging progress and sustainability for all. In the case of overtemperature, use a motor with a higher winding voltage or use a drive with a lower nominal supply voltage. RS485/Modbus: Incorrect number of monitor objects. Target velocity was not reached at motion blend position. Wait until the motor has come to a standstill (x_end = 1). Discover EcoStruxure Asset Advisor, a suite of cyber-secure, cloud based digital services for monitoring asset health and reducing downtime. The activation of a new operating mode is not possible, the error code is sent as the response to the activation command. Tutorial for troubleshooting the INF6 fault (internal option fault) on the Altivar ATV61 and ATV71 Variable Frequency Drives (VFD) typically caused by a loose option card or two serial cards. System inertia changes during operation. Recalculation for scaling is already running. Velocity too high for the encoder. Get monthly updates from Schneider Electric delivered right to your inbox. If you only have the cheap little LED seven segment display screen this is tougher to navigate. The specific type of device does not support this kind of file. If the winding voltage of the motor is lower than the nominal supply voltage of the drive, this may result in motor overtemperature due to high current ripple. The type of module detected in fieldbus slot is not supported by the drive. See also parameters _MSM_error_num and _MSM_error_entry for additional information. The drive only checks this for the first velocity jump. Operating mode has been activated but drive is not synchronized to external synchronization signal. o Lexium 62 Single Drive o Lexium 62 Double Drive o Lexium 62 Advanced Plus o Lexium 62 ILD o Lexium 62 ILM For information on the device reactions AD, BD1, and so on, refer to Device Reactions - Drive and Device Reactions - Power Supply. Get access to all resources, tools, and support with a single login to save time and operate your business efficiently. Schneider Electric - CCC Expert VSD - A.Dufoss - 16/10/2014 1. Verify correct settings for the parameter P1-23. There is no encoder available at the input specified via the parameter ENC_abs_source. Perform a Fault Reset. The ramp scaling of 'RAMPscaleDenom' and 'RAMPscaleNum' results in a scaling factor that is too small. Access occupied by another channel (for example: Commissioning software is active and fieldbus access was tried at the same time). CPU_A and CPU_B have different position values. Contact local Schneider Electric representative. Module in fieldbus slot not correctly detected. x}rd#_QxQJa#vZ?PMfq}3 2q!gT=D$lFpozs}?^IEetB||)W.8e|_4Y kMm^V~jj0o;;*lN:G9qp1{ ybPICQODe4QikLms8?~,L hXx+k3jsmP']av'nrNamw Not possible to set the absolute position for encoder 1. ESMSTART is configured for automatic start and must be high at start. Recalculation must be started within 30 seconds after initialization. Parameter outside of permissible value range. Limit switch to be approached not enabled. Encoder without temperature sensor, incorrect encoder connection. eSM module: Two types of multiple SLS selected at the same time. For more details, please read our D4: Sine/cosine inputs exceed DOS mismatch threshold. This chapter contains the following topics: o Diagnostic Messages Overview. Error detected during parameter switching. Get access to all resources, tools, and support with a single login to save time and operate your business efficiently. In this video we are going. Assign the signal input functions Positive Limit Switch, Negative Limit Switch and Reference Switch. Undervoltage in internal eSM power supply. Continuation of interrupted movement in operating mode Profile Position is not possible because another operating mode had been active in the meantime. The position difference between the index pulse and the switching point is insufficient. Download at www.schneider-electric.us/go/drives VW3A8114 Catalog number VW3A21212 Catalog number VW3A31852 SoMoveMobile Software VW3A21212 Altivar 212 Drive Technical Characteristics Environmental Specifications Temperature ratings Altitude ratings Humidity Vibration resistance Shock resistance Pollution degree - Short circuit at connector or encoder cable. Set the operating state to Ready To Switch On and restart commutation offset identification. Resolver: Loss of signal, position unreliable. Verify cable specifications, shield connection and EMC. o 8006 Program stopped. Verify signal input for reference value signal. eSM module: System error detected: Stack overflow, eSM module: System error detected: Program sequence control (communication), eSM module: System error detected: Program sequence control (Idle task), eSM module: System error detected: Firmware checksum, eSM module: Parameter outside of permissible value range. System error detected: Incompatible memory card, Memory card implicitly written by the device. Change the cycle time in the master controller to a cycle time supported by the drive or verify synchronization requirements. Position overflow, zero point is therefore no longer valid (ref_ok=0). eSM module: Parameter checksum incorrect (default values loaded). Internal nonvolatile memory not operative. Wire break or connected devices are inoperable. Find answers now. System error detected: Internal software error, System error detected: System stack overflow, System error detected: Division by zero (internal), System error detected: Overflow during 32 bit calculation (internal), System error detected: Size of data interface does not match, Parameter outside of value range (calculation error detected), System error detected: Internal range exceeded, System error detected: Calculated value cannot be represented as a 32 bit value, System error detected: 24 VDC below undervoltage threshold for shutdown, System error detected: Internal timer basis missing (Timer0), System error detected: Memory area locked, System error detected: Calculated value cannot be represented as a 16 bit value, System error detected: Impermissible function call from interrupt service routine. Not possible to execute command because negative software limit switch was triggered. Enjoy! System error detected: Jerk limitation with position offset after end of movement (additional info = offset in Inc.). The last saving procedure may not have been successful; the memory card may be inoperative. Error detected during parameter check (for example, reference velocity value for operating mode Profile Position is greater than maximum permissible velocity of drive). Restart the drive to activate the parameter functionality. These limit switches are not assigned to inputs. Verify correct deceleration ramp, rating of drive and braking resistor. Command is being processed or communication may be disturbed (EMC). o 8003 Controller boot finished. eSM module: Parameter cannot be written in this operating state. AL508. Each error message is identified by an error code. The motor only works with a PWM frequency of 16 kHz (motor nameplate entry). A start request for an operating mode has been received while a change of the operating mode was active. 2019 Schneider Electric. The specific type of device does not support this function or this parameter value. Verify the motor temperature. Verify the speed limits for machine operating modes Automatic Mode and Setup Mode and change them as required. Encoder has detected incorrect position evaluation. Original state of a parameter cannot be restored after an error was detected during recalculation of parameters with user-defined units. Position difference during the wake and shake procedure is too high. Verify that the system can easily be moved. Encoder signals subject to EMC interference (shield connection, cabling, etc.). Verify limit switch function and connection. Logical protocol error detected: Incorrect length or unsupported subfunction. After having started the synchronization mechanism, wait for 120 cycles before activating the operating mode. Schneider alt fault code | schneider altivar fault code manual | Diagnostics and troubleshooting HABSHI TECH 29.5K subscribers Subscribe 18K views 4 years ago KOLKATA Manual code of. At least two inputs have the same signal input function. List of Fault Codes for ATV61 | Schneider Electric Support Watch on Published for: Schneider Electric USA Attachment (s) Processing only possible with linear ramp. Configuration data incompatible with device. You will receive your welcome message soon. The signal input function does not support the selected debounce time. Fieldbus: An attempt was made to enable the power stage in the operating state Not Ready To Switch On. Restart the drive. Terminate the active operating mode or disable the power stage. Privacy Policy. Positive limit switch error detected (switch signal briefly enabled or switch overtraveled), Negative limit switch error detected (switch signal briefly enabled or switch overtraveled). eSM module: Parameter checksum error detected. Incorrect motor data entered by user (especially motor resistance, motor inertia (in case of rotary motors) or motor mass (in case of linear motors)). Verify that you really want the selected scaling factor. Verify that the motor is at a standstill at the beginning wake and shake procedure. During a configuration download, a communication error or an error in the external tool was detected. Position capture via signal input currently not possible. System not locked for configuration transfer. Reach out to our customer care team to receive more information, technical support, assistance with complaints and more. Incorrect setting for parameter WakeAndShakeGain. Under Faults- Causes- Remedies sections. Error detected by parameter management: Parameter (subindex) does not exist. Verify connection of STO_A and STO_B. Verify wiring and connected devices. Wait until the command in the operating mode has finished (x_end=1). Learn more and find impacted catalog numbers. I'd like to receive news and commercial info from Schneider Electric and its affiliates via electronic communication means such as email, and I agree to the collection of information on the opening and clicks on these emails (using invisible pixels in the images), to measure performance of our communications and improve them. Use a differently sized motor, if necessary. Set a speed limit not equal to zero for multiple SLS. Remove the cause of the stop and restart Autotuning. Af/Y"B]$gI^JLsE @ wl: \Xd6U5IItTMH]2eJ8PIIuv73s3pT9 Configuration error detected: Invalid BISS encoder parameter setting. Get answers you need by browsing topic-related Frequently Asked Questions (FAQ). First, switch from applying the holding brake manually to Automatic, then to releasing the holding brake manually. This applies to the following series: Altivar ATV12, ATV312, ATV32, ATV61, ATV71. F008 Internal CPU Internal microprocessor fault Turn the drive off and then back on again. System error detected: Communication with memory card, System error detected: Memory card bus is busy, System error detected: Nonvolatile memory checksum error (administration data), System error detected: Nonvolatile memory is write-protected. Change the value of the parameter ENC_abs_source. Verify that the external braking resistor is not active if one of the parameters RESext_ton, RESext_P or RESext_R has to be changed. Wait for Autotuning to finish before changing the parameter. We empower all to make the most of their energy and resources, ensuring Life Is On everywhere, for everyone, at every moment. Get answers you need by browsing topic-related Frequently Asked Questions (FAQ). I'd like to receive news and commercial info from Schneider Electric and its affiliates via electronic communication means such as email, and I agree to the collection of information on the opening and clicks on these emails (using invisible pixels in the images), to measure performance of our communications and improve them. The frequency of the external reference value signals (A/B signals, P/D signals or CW/CCW signals) is higher than the permissible value. Wait for the motion blend to complete before setting the next position. Product Line: ATV61 Environments: All Causes: Fault conditions Resolution: All trip codes and alarms can be found in the ATV61 Programming manual EN 1760649. The motor was not mounted properly, for example, it is thermally isolated. Medium Voltage Distribution and Grid Automation, Product Documentation and Software Downloads, Panelboards / Switchboards and Switchgear, Controllers, Expansion Modules, Servers & HMIs, Power Metering and Energy Monitoring Systems, Power Quality and Power Factor Correction, Integrated Power and Control Solutions (IPaCS) Equipment, Low Voltage/Medium Voltage Prefab Substations, Pushbuttons, Switches, Pilot Lights, Control Stations and Joysticks, Data Center Security and Environmental Monitoring. Cyclic communication: Synchronization signal missing. Jog error detected (additional info = detailed error code). Drive Profile Lexium: Write request with incorrect data type. Enjoy! Direction-dependent SLS is active, but no speed limit greater than 0RPM has been specified in the parameter eSM_v_maxSetup or in parameter eSM_SLSnegDirS. Connector not connected to module or not connected to motor/encoder. Fault detection codes that cannot be cleared automatically (continued), Enhancements made to version V1.2 in comparison to V1.1, Using the drive with motor having a different size, Use with a smaller rated motor or without a motor, Single-phase supply voltage: 100120 V 50/60 Hz, Single-phase supply voltage: 200240 V 50/60 Hz, Three-phase supply voltage: 200240 V 50/60 Hz, EMC mounting plate: size 1 VW3A9523, size 2 VW3A9524 or size 3 VW3A9525 to be ordered separately, ATV12H075F1, ATV12H075M2 AND ATV12H075M3 - GROUND CONTINUITY HAZARD, Access to the terminals if you use stripped wire cables, Access to the line supply terminals to connect ring terminals, HAZARD OF ELECTRIC SHOCK, EXPLOSION OR ARC FLASH, M External reference value -400 to +400 Hz -, M Analog input virtual 0 to 100 % of HSP -, M External reference value -400 Hz to 400 Hz -, M Application Overload threshold 70 to 150% of nCr 90% of of nCr, M Time delay before automatic start for the underload fault, M Motor frequency threshold 0 to 400 Hz 50 or 60 Hz, M Motor current threshold 0 to 1.5 In (1) InV, M Motor thermal state threshold 0 to 118% of tHr 100%, M Automatic DC injection current 0 to 120% of nCr 70%, M Automatic DC injection time 0.1 to 30 s 0.5 s, M Low speed operating time 0.1 to 999.9 s nO, M PI feedback supervision function time delay 0 to 600 s 0 s, M Maximum frequency detection hysteresis 0 to HSP 0 Hz, M Time delay before automatic start for the overload fault, M Application Underload threshold 20 to 100% of nCr 60%, M Starting frequency of the auxiliary pump 0 to tFr HSP, M Time delay before starting the auxiliary pump, M Ramp for reaching the auxiliary pump nominal speed, M Auxiliary pump stopping frequency 0 to tFr 0 Hz, M Ramp for auxiliary pump stopping 0 to 999.9 s 2 s, M Zero flow detection activation threshold 0 to 400 Hz 0 Hz, M Zero flow detection offset 0 to 400 Hz 0 Hz, Single variable mode - 1 single variable speed pump, M Current limitation 0.25 to 1.5 In (1) 1.5 In, RISK OF DAMAGE TO THE MOTOR AND THE DRIVE, M Current limitation 2 0.25 to 1.5 In (1) 1.5 In, M Com scanner write address value 2 LFRD value, Assistance with maintenance, detected fault display. D6: Sine/cosine inputs below LOS threshold. The safety function STO was activated in the operating state Operation Enabled. For more details, please read our eSM module: System error detected: SPI framing error detected, eSM module: Input states channel A and channel B are not identical. eSM module: System error detected: Boot program: Invalid address. Deceleration after HALT request still running. Code 8503 / external diag. Special login is required for Manufacturing Test Firmware, Position capturing has not yet been activated. Example: Start of backlash compensation while autotuning/manual tuning is active. o 8004 Program started. Welcome the the Schneider Electric French website. Change eSM state to write this parameter. eSM Disable requires the safety module eSM to be in operating state Operation Enabled. Excessively high ambient temperature due to, for example, dust. If monitoring functions of the drive detect an error, the drive generates an error message. Setting the offset position is not possible. Find answers now. Incorrect system inertia for velocity observer calculations. Start a movement before the motion blend is activated. Verify wiring of the external braking resistor. Command is not permissible during deceleration. Reach out to our customer care team to receive more information, technical support, assistance with complaints and more. Position scaling of POSscaleDenom and POSscaleNum results in a scaling factor that is too small. CPU_A and CPU_B have different velocity values. Incorrect wiring or inoperative cable for Hall signals of encoder 2. Activation of a new operating mode is not possible while another operating mode is still active. eSM module: Safely Limited Speed (SLS) exceeded in machine operating mode Automatic Mode. Use supported type of fieldbus module. [[^k.Feh h"OD0xdVxd{w8:s{sZ``# Fm8N):Qmk ub?F93 Rm,Nqy}-T/ ]0j6(lT~7)hj%a|@]Wv0@|5.e ve i$%XH}Y #pwU]]\RF)$1>~3S{1phDs61dLhQ$ ejL$fD5 )b&h@g6fIwPevlL 8Aur]F\>] 'Q`4`/w!{ R(catnGqJNo;-,@DG#uPf7e: ciMv?,(q;P',]PB1;. If the detected error persists, deactivate the velocity observer. The drive contained an invalid configuration before the recalculation was started. eSM module: System error detected: States of eSM state machines not identical, eSM module: Output AUXOUT1 (cross fault to another output detected). Incorrect values in parameter ENCDigSSIResSgl or ENCDigSSIResMult. Incorrect sequence of steps for scaling (fieldbus). Motor short circuit and disabling of the power stage. eSM module: Timeout during parameter download (default values loaded), eSM module: Parameter checksum cannot be written in this operating state. Parameter of CPU_A is not identical to parameter of CPU_B. Configuration is blocked by another access channel. Deactivate jerk filter processing for Electronic Gear or use processing method 'Position synchronization without compensation movement'. All rights reserved. 28K views 4 years ago How to Altivar Machine ATV320 | Schneider Electric Tutorial for troubleshooting an EPF1 Fault (External Fault) on the Altivar ATV320 Variable Frequency Drive (VFD).. System error detected. 2019 Schneider Electric. Maximum position deviation between motor encoder and machine encoder exceeded. Start reference movement with negative direction (for example, reference movement to negative limit switch) and activate the positive limit switch (switch in opposite direction of movement). Encoder signals subject to EMC interference (shield connection, wiring, etc.). Code 8503 / external diag. Not possible to execute command because positive software limit switch was triggered. Clear break condition with command Fault Reset. Improve EMC, verify grounding and shield connection. The position deviation has become excessively high due to a velocity limitation or the release of direction. List of the Error Messages Sorted by Error Code. Verify correct wiring of the inputs of the safety function STO. Code W P 078 e 700C Diag. The selected operating mode is not available. Motor subjected to vibration or shock when stopped after activation of the switch signal. Fieldbus module: Controlling communication channel has been closed, Fieldbus module: Internal communication error detected, Fieldbus module: I/O data mapping error detected, Fieldbus module: Nonvolatile memory error detected in module.
Police Officer Scenarios,
Salary Of Fireman In Odisha,
Articles S